Welcome to a comprehensive exploration of the 3rv2011-1ka10 Datasheet. This crucial document serves as the definitive resource for understanding and utilizing the 3RV2011-1KA10 circuit breaker, a vital component in electrical systems. Whether you're an engineer, technician, or a curious individual, delving into this datasheet will equip you with the knowledge to ensure safe and efficient motor operation.
Understanding the 3rv2011-1ka10 Datasheet and Its Applications
The 3rv2011-1ka10 Datasheet is more than just a collection of technical specifications; it's the blueprint for a powerful motor protection device. At its core, the 3RV2011-1KA10 is a manual motor starter and protector designed to safeguard electric motors from a variety of electrical faults. It offers crucial protection against overloads, short circuits, and phase failures, which can lead to costly damage and downtime if left unchecked. The importance of this datasheet lies in its ability to provide precise details for selecting, installing, and operating this protective device correctly, thereby guaranteeing the longevity and reliability of your motor applications.
Within the 3rv2011-1ka10 Datasheet, you'll find detailed information on the breaker's electrical characteristics, mechanical dimensions, and operational parameters. This data is essential for integrating the 3RV2011-1KA10 into various industrial and commercial settings. For instance, the datasheet will outline:
- Rated operational voltage
- Rated current range
- Trip class settings
- Short-circuit breaking capacity
These specifications allow for precise matching of the circuit breaker to the specific motor it will protect, ensuring optimal performance and safety. It’s also common to find information regarding connection types and mounting options, facilitating seamless integration into existing or new control panels.
The practical applications of the 3RV2011-1KA10, as detailed in its datasheet, span across numerous industries. From simple pump applications to complex conveyor systems and machine tools, the need for robust motor protection is universal. The datasheet empowers users to make informed decisions, such as:
- Determining the correct size of the 3RV2011-1KA10 for a given motor load.
- Understanding the tripping curves to predict how the breaker will react under different fault conditions.
- Ensuring compliance with relevant safety standards and regulations.
Consider a scenario where a motor experiences an unexpected overload. The 3rv2011-1ka10 Datasheet will specify the exact current threshold and time delay before the breaker trips, preventing damage to the motor windings. Similarly, in the event of a short circuit, the datasheet will confirm the breaker's ability to interrupt the fault current rapidly, protecting both the motor and the surrounding electrical infrastructure. Below is a simplified table illustrating typical rating information found:
| Parameter | Typical Value |
|---|---|
| Rated Insulation Voltage | 690 V |
| Rated Service Voltage | 400 V |
| Trip Setting Range | 0.45 - 1.0 A |
By thoroughly reviewing the 3rv2011-1ka10 Datasheet, you gain the confidence to implement effective motor protection strategies. This document is your indispensable companion for understanding the full capabilities and recommended usage of the 3RV2011-1KA10 circuit breaker.
For an in-depth understanding of the 3RV2011-1KA10 and its optimal deployment, we strongly encourage you to consult the provided 3rv2011-1ka10 Datasheet. It contains all the necessary technical specifications and guidelines to ensure your electrical systems are protected and perform at their best.